Safeline STANDARD SERIES Manual de Instruções Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 81
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
NOTES
1) LINK 2 MUST BE FITTED IF THE MODULE HARDWARE IS LESS THAN VERSION 62 (INTRODUCED 25/10/93) AND DOES NOT
INCLUDE REJECT CONFIRMATION.
2) METAL DETECTION RELAY CONTACTS - RL1. THE RELAY CONTACTS CHANGE FROM THE STATE SHOWN WHEN METAL
IS DETECTED
3) SYSTEM FAULT RELAY CONTACTS - RL2.(OPTIONAL). THE RELAY CONTACTS CHANGE FROM THE STATE SHOWN IF THE
REJECT CONFIRMATION UNIT SIGNALS A REJECT FAULT OR THE METAL DETECTOR SIGNALS A HEAD OR MODULE
FAULT.
Fig. 6A Layout of Components and Terminals for P/S Connection PCB issue - 6 and 7
Page 8
Layer 1
19
123456789101112131415161718
29 3 0 31 32 33 3 4 35 36 37 38 39 40 41 42 4 3 44 45 46 4 7 48 49 50 51 52 53 5 4 55 56
20 21 22 2 3 24 25 26 27 28
57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74
19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
20 21 22 23 24 25 26 27 28
PACK
SENSOR
SPEED
SENSOR
RCU
SENSOR
DETECTOR
HEAD
CABLE
CONNECTIONS
RED
BLACK
WHITE
BLUE
BROWN
PURPLE
SPARE
YELLOW
TURQUOISE
ORANGE
GREEN
GREY
PINK
BLUE
RED
BLACK
OPTIONAL
REJECT CONFIRMATION
UNIT CIRCUIT BOARD
FUSE F1: 3.15A (T)
(ON POWER SUPPLY MODULE
UNDERNEATH THE
CONNECTIONS BOARD)
NOT A USER SERVICABLE PART
FUSE: F2: 1.0A (T)
or
ELECTRONIC FUSE
LIVE
NEUTRAL
EARTH
EARTH
SW. LIVE
SW. NEUTRAL
N/O
COMMON
N/C
N/C
COMMON
N/O
SPARE
N/O
COMMON
N/C
N/C
COMMON
N/O
LATCH
LATCH
RESET
RESET
TXD
RXD
GND
REMOTE RESET
DETECT SIGNAL
DETECTOR
RS232
CABLE
85 TO 265 V AC
47 TO 440 Hz
RL1
(NOTE 2)
RL2
(NOTE 3)
USER
RS232
LINK
LINK 2 (NOTE 1)
SPARE
+15 V
0 V
OUTPUT
.
SPARE
+15 V
0 V
OUTPUT
.
SPARE
+15 V
0 V
OUTPUT
.
57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74
DETECTOR HEAD
CABLE CONNECTIONS
YELLOW/RED
RED/BLACK
RED/BROWN
WHITE/RED
YELLOW/BLUE
WHITE/BLUE
BLUE/BLACK
ORANGE/BLUE
SCREEN
AUX1
AUX2
TXD2B
RXD2B
TXD1
RXD1
RTS1
CTS1
USER COM1 AND COM2
(TERMINALS 58 TO 61 ARE
RESERVED FOR
FUTURE DEVELOPMENT)
CONCLAMP AND GLAND FITTING
(SEE FIG. 6B AND 6C)
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 80 81

Comentários a estes Manuais

Sem comentários